Open frame type GF1 Series single-phase water-cooled diesel generator sets
The formation instructions of diesel generating sets 1. 3-15KW series of ordinary diesel generating sets have been provided with high quality water-cooled (condenser) diesel engine, those engine can work well in every kinds conditions. 2. The structure of generating sets, the engine has been coupled with alternator though v-belt or coupled directly with alternator, both of them have been installed on the basis of anti-shock pad , the gen-sets has been fixed on the frame of steel pipes which has for wheels. 3. Other features Easy to operate: it’s easy to operate and maintain control panel capacitor type voltage regulator no-fuse circuit breaker over-current protection wheels type design double-shaft balance design electric starting. Other mail performance: 1. Voltage stead-state regulation ±10% fluctuation ratio 1.5% Transient-state regulation -15~20% stead time 5s Frequency stead-state regulation ±1% stead time 5s 2. The noise of gen-sets should be no more than 85db(a) The fuel consumption is no more than 2.5kg/kw.h.
The new cooling system with the condensation type, it is the excellent cooling performance. More compact panel board, easy to control. Safely electrical starting system, for easy to start.
GF2 series open frame type water-cooled diesel generator sets
The formation instruction of diesel generating sets 1. Diesel generating sets Diesel generating sets include diesel engine, alternator and control box and all the alternators. 2. Stating method of gen-sets. a). manual switcher b). automatic starting wholly: when electric supply has been stopped, the gen-sets can start three times automatically in 3-28 seconds (time can be adjustable) between electric supply and gen-sets need 6-8 seconds. It will spend 12 seconds to accept load when electric supply resumed, gen-set will maintain 23-230 seconds, then closes down automatically. 3.Control system Apparatus: voltmeter, frequency meter, amperage meter, voltmeter of battery, meter of water temp, oil meter . control section: starting handler, key type switch, inductive type self-protection switch, and indicator. Other main performance: 1. Voltage stead-state regulation ±1% fluctuation 1.5% Transient-stater egulation -15~20% stead time 5s Frequency Stead-state regulation 5% fluctuation ratio 1.5% Transient-state regulation ±10% stead time 5s 2. The noise of gen-sets should no more than 85db(a) The fuel consumption in no more than 2.5kg/kw.h. Technical data